NEOTECH

testing

Certified Brake Testing: 6 Metres Shorter, 157,000 Cycles

A robot-actuated 100 N pedal test from 100 km/h cut stopping distance by 6 metres against OE. Calipers then survived 157,000 cycles from −30°C to 120°C. Here are the numbers and how they were measured.

Updated

Stopping distance from 100 km/h — Neotech kit against original equipmentTwo braking runs from the same start line at 100 km/h under a constant 100 newton pedal force applied by a robotic actuator. The original equipment brakes come to rest six metres further down the road than the Neotech kit. Absolute distances are not shown because only the difference was published.100 km/h — brakes appliedNEOTECH KITORIGINAL EQUIPMENT6 m shorterSame start line
Tested under TS (Korea Transportation Safety Authority) regulation: 100 km/h to rest, 100 N constant pedal force applied by a robotic actuator. Bar lengths are illustrative — only the 6 m difference was measured, and absolute stopping distance varies by vehicle.
−6 m
Shorter than OE, from 100 km/h
100 N
Constant pedal force, robot-applied
157,000
Caliper cycles completed
−30 … 120 °C
Thermal bands tested

Brake marketing is full of unfalsifiable claims. These two are not ours to interpret — both tests were run to published parameters under Korea's official automotive tuning certification framework.

Stopping distance: 6 metres shorter than OE

The test was conducted under TS (Korea Transportation Safety Authority) test procedures.

ParameterValue
Pedal force100 N, constant
Applied byRobotic actuator
Speed100 km/h to 0
ComparisonNeotech kit vs. original equipment
Result6 metres shorter

The robotic actuator matters more than it sounds. Human drivers modulate — they build pressure at different rates, and they do it differently on the tenth run than the first. A robotic actuator applied the same 100 N pedal force in both configurations, reducing driver-induced variation and providing a highly repeatable comparison between the OE and Neotech brake systems.

Endurance: 157,000 cycles across three thermal environments

Testing was carried out at the Korea Automotive Technology Institute (KATECH) under the official certification procedures established for automotive tuning components in Korea. The calipers ran continuously at 6.9 MPa across three temperature bands.

EnvironmentTemperaturePressureCycles
Low−30 ± 5 °C6.9 MPa7,000
Normal20 ± 5 °C6.9 MPa120,000
High120 ± 5 °C6.9 MPa30,000
Total157,000

The calipers completed all three phases with full functionality and structural integrity intact, passing every durability requirement.

The thermal spread is the interesting part. Seals that are compliant at 20 °C can go hard and leak at −30 °C, and materials that hold shape cold can relax at 120 °C. Running the same pressure across all three bands tests the assembly at both ends of its working envelope rather than in the comfortable middle.

Read next